Welcome to the Ideal Isar HE 24 Manual, your comprehensive guide to understanding, installing, and operating the Ideal Isar HE 24 boiler efficiently and safely.
1.1 Overview of the Ideal Isar HE 24 Boiler
The Ideal Isar HE 24 is a high-efficiency combination boiler designed to provide both central heating and instantaneous domestic hot water. With a compact design and user-friendly controls, it is suitable for a wide range of heating demands. The boiler operates efficiently, achieving high performance while minimizing energy consumption. It is compatible with natural gas and features a robust construction for long-term reliability. The Isar HE 24 is an ideal solution for modern heating needs, offering flexibility and comfort.
1.2 Purpose and Scope of the Manual
This manual is designed to provide detailed guidance for the installation, operation, and maintenance of the Ideal Isar HE 24 boiler. It serves as a comprehensive resource for engineers, technicians, and homeowners to ensure safe and efficient use. The manual covers technical specifications, safety precautions, and troubleshooting procedures. It also outlines compliance with regulatory standards and offers best practices for optimal performance. By following the instructions in this manual, users can maximize the boiler’s efficiency and longevity while maintaining safety standards.
Key Features of the Ideal Isar HE 24 Boiler
The Ideal Isar HE 24 boiler offers high efficiency, compact design, and reliable performance, making it an excellent choice for central heating and hot water needs.
2.1 Technical Specifications
The Ideal Isar HE 24 boiler features a net CV kW input range of 8.8 to 23.4, with a maximum DHW flow rate of 9.6 l/min at 35°C. It operates on natural gas (G20, 20mbar) and includes a cast aluminum heat exchanger for durability. The boiler is compact, weighing approximately 29kg, and has a gas supply connection of Rc 1/2. Its energy efficiency aligns with regulatory standards, ensuring optimal performance and reliability for both central heating and domestic hot water systems.
2.2 Energy Efficiency and Performance
The Ideal Isar HE 24 boiler delivers high energy efficiency, achieving an A-rated performance for both central heating and domestic hot water. Its advanced design minimizes energy waste, ensuring optimal fuel utilization. With a seasonal space heating efficiency of up to 90%, it significantly reduces energy consumption and operational costs. The boiler’s high efficiency also results in lower carbon emissions, making it an environmentally friendly choice. Additionally, its rapid response to demand ensures consistent heating and hot water supply, enhancing overall performance and user satisfaction.
Installation and Servicing Guidelines
Proper installation and regular servicing are crucial for optimal performance. Ensure all gas connections, ventilation, and electrical links comply with safety standards. Routine servicing maintains efficiency.
3.1 Step-by-Step Installation Instructions
- Ensure the installation site is prepared, with clear access and proper ventilation.
- Unpack the boiler and verify all components are included and undamaged.
- Position the boiler on a suitable wall, following the manual’s mounting guidelines.
- Connect the gas supply, ensuring compliance with safety standards and regulations.
- Install the necessary water and electrical connections as per the wiring diagram.
- Test the system for leaks and proper functionality before handing over to the user.
Always follow safety protocols and use only approved parts.
3.2 Servicing Recommendations and Schedules
Regular servicing is essential to maintain the efficiency and safety of your Ideal Isar HE 24 boiler. It is recommended to have the boiler serviced annually by a Gas Safe Registered Engineer. Key areas to inspect include the heat exchanger, burner, and flue for any signs of damage or wear. Ensure all components are clean and functioning properly. Replace any worn or faulty parts using only Ideal-approved spares. Always follow the manufacturer’s guidelines and keep a record of servicing for future reference.
Operating the Ideal Isar HE 24 Boiler
Learn how to efficiently operate the Ideal Isar HE 24 boiler, including using the programmer for scheduling heating and hot water, and understanding the display indicators.
4.1 User Controls and Programmer Functions
The Ideal Isar HE 24 boiler features intuitive user controls and a programmer that allows you to set specific times for central heating and domestic hot water operation. The programmer enables you to customize your heating schedule, optimizing comfort and energy efficiency. The display provides clear indicators for system status, such as when heating or hot water is active. Additionally, the boiler includes a fault code system to help diagnose and resolve issues quickly. Regular updates ensure compatibility with the latest energy-saving features.
4.2 Understanding Fault Codes and Resolutions
The Ideal Isar HE 24 boiler utilizes a fault code system to identify issues, displayed on the control panel. Common codes include “Call for Heat” or “Low System Pressure,” with detailed explanations in the manual. Resolutions often involve simple checks, such as ensuring gas supply or verifying system pressure. For persistent faults, consulting a Gas Safe Registered Engineer is recommended to ensure safety and compliance. Regular servicing can prevent many issues, maintaining optimal performance and efficiency.
Maintenance and Troubleshooting
Regular maintenance ensures the Ideal Isar HE 24 boiler operates efficiently. Troubleshooting guides in the manual help diagnose common issues, preventing major repairs and ensuring safety.
5.1 Routine Maintenance Tasks
Regular maintenance is crucial for the Ideal Isar HE 24 boiler’s optimal performance. Tasks include checking the gas supply, inspecting the flue, and cleaning the heat exchanger. Annual servicing by a qualified engineer is recommended to ensure safety and efficiency. Additionally, users should monitor water pressure and bleed radiators as needed. Always refer to the manual for detailed instructions and adhere to the manufacturer’s guidelines to maintain warranty validity and prevent potential issues.
5.2 Common Issues and Diagnostic Procedures
Common issues with the Ideal Isar HE 24 boiler include error codes such as low water pressure, ignition failures, or diverter valve problems. To diagnose, check the system’s pressure, ensure proper gas supply, and inspect the flue for blockages. For error codes, refer to the fault code table in the manual. If issues persist, consult a Gas Safe Registered Engineer. Regular servicing and adherence to maintenance schedules can help prevent these problems and ensure reliable operation. Always follow safety guidelines during diagnostics.
Safety Precautions and Compliance
This section outlines essential safety precautions and compliance requirements for the Ideal Isar HE 24 boiler, ensuring safe operation and adherence to regulatory standards through proper installation and regular maintenance.
6.1 Gas Safety and Installation Requirements
The Ideal Isar HE 24 boiler must be installed by a Gas Safe Registered Engineer, adhering to current Gas Safety regulations. Ensure all connections comply with BS 6798 standards. Proper ventilation and flue installation are critical to prevent carbon monoxide risks. Use genuine parts to maintain safety and performance. Regular servicing by a qualified technician is essential to uphold gas safety standards and warranty validity. Always follow installation guidelines to ensure compliance and safe operation of the boiler.
6.2 Compliance with Regulatory Standards
The Ideal Isar HE 24 boiler is designed to meet all relevant regulatory standards, including EU directives and UK Building Regulations. It complies with the ErP Directive for energy efficiency and the Gas Appliance Regulation for safety. The boiler is CE marked, ensuring conformity with European safety, health, and environmental requirements. Always ensure installation adheres to local regulations and that the installer is Gas Safe registered. This guarantees safe and efficient operation while meeting legal obligations.
Warranty and Customer Support
Ideal Isar HE 24 boilers come with a comprehensive warranty, offering extended protection for parts and labor. Dedicated customer support is available for inquiries, ensuring prompt assistance and resolving issues efficiently. Visit www.idealgas.co.uk for more details on warranty terms and support options.
7.1 Warranty Terms and Conditions
The Ideal Isar HE 24 boiler is backed by a comprehensive warranty, offering protection for parts and labor under normal use. The warranty period varies depending on the component, with the heat exchanger typically covered for up to 10 years. Registration within 30 days of installation is required to validate the warranty. Proper installation and annual servicing by a Gas Safe engineer are essential to maintain coverage. For full details, refer to the warranty terms outlined in the manual or visit www.idealgas.co.uk.
7.2 Contact Information for Customer Service
For assistance with your Ideal Isar HE 24 boiler, contact Ideal customer service at 0800 028 028 28 (UK) or 1800 804 900 (Ireland). Email inquiries can be sent to customer.service@idealheating.com. Visit their official website at www.idealgas.co.uk for additional resources, including FAQs and downloadable manuals. Customer service is available Monday to Friday, 8:00 AM to 5:00 PM, excluding bank holidays. Ensure you have your boiler model and serial number ready for efficient support.